Description
We can supply everything from the smallest to the largest implementation. Areas of application can be Transmission of measurement signals or current/voltage supply. Our customers use the feedthroughs in vacuum chambers, nuclear technology, radiation measurement, fuel cells, combustion technology, X-ray technology, high-temperature battery technology, chemical process technology, X-ray inspection and satellite technology.
General information on current feedthroughs
Vacuum tightness up to 10-9 mbarL/s
Insulation resistance > 1012 Ohm, tested up to 10 kV DC
Ceramic surface glazed on the outside
Operating temperature: -180° C to +600° C
Conductor materials: Cu, NiFe42 or Ni
Voltage: up to 8 kV
Current: up to 80 A